Ces informations sont fournies en tant que telles, et je n'assure aucune garantie quant ŕ leur véracité ou utilité :-) Elles sont Copyright US Robotics, et concernent parfois uniquement que le modem Courier V32bis Fax with ASL AT$ --- &$ HELP, Ampersand Commands %$ HELP, Percent Commands A/ Repeat Last Command A> Continuously Repeat Command AT Command Mode Prefix A Answer Call Bn n=0 v32 bis CCITT Answer Seq n=1 HST ; Bell Answer Seq Cn n=0 Transmitter Off n=1 Transmitter On Dn Dial a Telephone Number n=0..9#*TPR,;"W@!()- DL Dial Last Phone Number DSn Dial Stored Phone Number (0-3) D$ HELP, Dial Commands En n=0 No Command Echo n=1 Echo Command Chars Fn n=0 Online Echo n=1 No Online Echo Hn n=0 On Hook (Hang Up) n=1 Off Hook In n=0 Product Code n=1 Checksum n=2 RAM Test n=3 Call Duration/Clock / Product ID string n=4 Current Settings n=5 NVRAM Settings n=6 Link Diagnostics n=7 Product Configuration n=9 Pnp Enumeration Screen n=10 Dial Security Status n=11 Link Diagnostics Kn n=0 Call Duration Mode n=1 Real Time Clock Mode Ln n=0 Low Speaker Volume n=1 Low Speaker Volume n=2 Med Speaker Volume n=3 Hi Speaker Volume Mn n=0 Speaker Off n=1 Speaker On Until CD n=2 Speaker Always On n=3 Speaker Off During Dial On n=0 Return Online n=1 Return Online & Retrain n=2 Return Online & Speed Shift P Pulse Dial Qn n=0 Result Codes Sent n=1 Quiet (No Result Codes) n=2 Verbose/Quiet On Answer Sr=n Sets Register "r" to "n" Sr? Query Register "r" S$ HELP, S Registers T Tone Dial Vn n=0 Numeric Responses n=1 Verbal Responses Xn n=0 Basic Result Codes n=1 Extended Result Codes n=2-7 Advanced Result Codes Yn n=0 Next Reset to &W0 settings n=1 Next Reset to &W1 settings n=2 Next Reset to &F0 settings n=3 Next Reset to &F1 settings n=4 Next Reset to &F2 settings Zn n=0 Y setting determines reset n=1 Reset to &W0 settings n=2 Reset to &W1 settings n=3 Reset to &F0 settings n=4 Reset to &F1 settings n=5 Reset to &F2 settings +++ Escape Code > Repeat until canceled $ HELP, Command Summary / Pause 125 ms AT&$ ---- &An n=0 Disable /ARQ Result Codes n=1 Enable /ARQ Result Codes n=2 Enable /Modulation Codes(HST/V32) n=3 Enable /Extra Result Codes &Bn n=0 Floating DTE Speed n=1 Fixed DTE Speed n=2 DTE Speed Fixed When ARQ &Cn n=0 CD Always On n=1 Modem Controls CD &Dn n=0 Ignore DTR n=1 On-Line Command Mode n=2 DTE Controls DTR n=3 Reset ON DTR Loss &Fn n=0 Load Factory Configuration (Hardware Flow Control) n=1 Hardware Flow Control Cnfg. n=2 Software Flow Control Cnfg. n=3 HST/Cellular w/ HW FC Cnfg. &Gn n=0 No Guard Tone n=1 550 Hz Guard Tone n=2 1800 Hz Guard Tone &Hn n=0 Disable TX Flow Control n=1 CTS n=2 Xon/Xoff n=3 CTS and Xon/Xoff &In n=0 Disable RX Flow Control n=1 XonXoff (local & remote) n=2 XonXoff Chars Filtered(local only) n=3 HP Enq/Ack Host Mode n=4 HP Enq/Ack Terminal Mode n=5 Xon/Xoff for non-ARQ Mode &Kn n=0 Disable Data Compression n=1 Auto Data Compression n=2 Enable Data Compression n=3 Selective Data Compression(V42b) &Ln n=0 Disable Leased Line n=1 Enable Leased Line n=2 Enable Cellular (HST mode only) &Mn n=0 Normal Mode n=1 Synchronous Mode(async comm) n=4 ARQ/Normal Mode n=5 ARQ Mode n=6 V.25bis (char oriented) n=7 V.25bis HDLC &Nn n=0 Highest Link Speed n=1 300 bps n=2 1200 bps n=3 2400 bps n=4 4800 bps n=5 7200 bps n=6 9600 bps n=7 12000 bps n=8 14400 bps n=9 16800 bps n=10 19200 bps n=11 21600 bps n=12 24000 bps n=13 26400 bps n=14 28800 bps n=15 31200 bps n=16 33600 bps n=17 28000 bps n=18 29333 bps n=19 30666 bps n=20 32000 bps n=21 33333 bps n=22 34666 bps n=23 36000 bps n=24 37333 bps n=25 38666 bps n=26 40000 bps n=27 41333 bps n=28 42666 bps n=29 44000 bps n=30 45333 bps n=31 46666 bps n=32 48000 bps n=33 49333 bps n=34 50666 bps n=35 52000 bps n=36 53333 bps n=37 54666 bps n=38 56000 bps n=39 57333 bps &Pn n=0 N.American Pulse Dial n=1 UK Pulse Dial &Rn n=0 CTS Follows RTS(RTS/CTS delay) n=1 Ignore RTS n=2 RX to DTE/RTS &Sn n=0 DSR Always On n=1 Modem Controls DSR n=2 Pulse DSR, CTS=CD n=3 Pulse DSR n=4 DSR = DCD &Tn n=0 End Test n=1 Analog Loopback (ALB) n=3 Digital Loopback (DLB) n=4 Grant Remote DLB n=5 Deny Remote DLB n=6 Remote Digital Loopback n=7 Remote DLB With Self Test n=8 ALB With Self Test &Un n=0 Variable link rate floor. n=1 Minimum link rate 300 bps n=2 Minimum link rate 1200 bps n=3 Minimum link rate 2400 bps n=4 Minimum link rate 4800 bps n=5 Minimum link rate 7200 bps n=6 Minimum link rate 9600 bps n=7 Minimum link rate 12000 bps n=8 Minimum link rate 14400 bps n=9 Minimum link rate 16800 bps n=10 Minimum link rate 19200 bps n=11 Minimum link rate 21600 bps n=12 Minimum link rate 24000 bps n=13 Minimum link rate 26400 bps n=14 Minimum link rate 28800 bps n=15 Minimum link rate 31200 bps n=16 Minimum link rate 33600 bps n=17 Minimum link rate 28000 bps n=18 Minimum link rate 29333 bps n=19 Minimum link rate 30666 bps n=20 Minimum link rate 32000 bps n=21 Minimum link rate 33333 bps n=22 Minimum link rate 34666 bps n=23 Minimum link rate 36000 bps n=24 Minimum link rate 37333 bps n=25 Minimum link rate 38666 bps n=26 Minimum link rate 40000 bps n=27 Minimum link rate 41333 bps n=28 Minimum link rate 42666 bps n=29 Minimum link rate 44000 bps n=30 Minimum link rate 45333 bps n=31 Minimum link rate 46666 bps n=32 Minimum link rate 48000 bps n=33 Minimum link rate 49333 bps n=34 Minimum link rate 50666 bps n=35 Minimum link rate 52000 bps n=36 Minimum link rate 53333 bps n=37 Minimum link rate 54666 bps n=38 Minimum link rate 56000 bps n=39 Minimum link rate 57333 bps &Vn Sync. serial port rate &Wn n=0 store configuration 0 n=1 store configuration 1 &Xn n=0 DCE Synchronous Clock n=1 DTE Synchronous Clock n=2 RX Clock is Source &Yn n=0 Destructive n=1 Destructive/Expedited n=2 Nondest./Expedited n=3 Nondest./Unexpedited &Zn=s Store Phone Number &Zn=L Store Last Phone Number &Zn? Query Phone Number &ZC=s Write the following command string "s" to NVRAM AT%$ ---- %An= Security Account Information Command Structure %An=PW,ACCT E,DIAL B,NEW#,PH# n = (0-9) PW = Password ACCT E = Account Enable DIAL B = Dial Back Enable NEW# = New Dial Back # PH# = Dial Back Phone # %Bn Remote DTE Data Rate n=0 110 bps n=1 300 bps n=2 600 bps n=3 1200 bps n=4 2400 bps n=5 4800 bps n=6 9600 bps n=7 19200 bps n=8 38400 bps n=9 57600 bps n=10 115200 bps %Cn n=0 Defer Configuration n=1 Revert Configuration n=2 Execute Configuration %E=n Erase Account Information n=1 Erase Local Access Psw n=2 Erase Autopass Psw n=3 Erase Accounts Psw n=4 Erase Accounts Phone # n=5 Erase Accounts Status %Fn Remote DTE Data Format n=0 8, No parity n=1 7, Mark parity n=2 7, Odd parity n=3 7, Even parity %L=PWn Security Local Access Psw PWn = (0-9) %Nn V.25bis Synchronous Clock Rate n=0 RESERVED n=1 RESERVED n=2 1200 bps n=3 2400 bps n=4 4800 bps n=5 7200 bps n=6 9600 bps n=7 12000 bps n=8 14400 bps n=9 16800 bps n=10 19200 bps %Pn=s Store Remote Access Pswd n=0 Query Access Only n=1 Full Configuration %Pn? Query Remote Access Pswd n=0 Query Access Only n=1 Full Configuration %S= Psw To Grant Local Access %T Touch Tone recognition %V=PWn Security Autopass Psw PWn = (0-9) ATS$ ---- S0 Ring to Answer On S1 Counts # of Rings S2 Escape Code Char S3 Carriage Return Char S4 Line Feed Char S5 Backspace Char S6 Wait Time/Dial Tone (sec) S7 Wait Time/Carrier (sec) S8 Comma Time (sec) S9 Carrier Detect Time (1/10sec) S10 Carrier Loss Time (1/10sec) S11 Dial Tone Spacing (msec) S12 Escape Code Time (1/50sec) S13 Bit Mapped 1 = Reset On DTR Loss 2 = Do Originate in Auto Answer (Reduced Non-ARQ TX buffer) 4 = No Pause Before Result Codes (Set DEL=Backspace) 8 = Do DS0 On DTR 16 = Do DS0 On Reset 32 = Reserved 64 = Disable MNP Level 3 (Disable Quick Retrains) 128 = Hardware Reset (Escape Code Hang Up) S14 Bit Mapped 1 = Escape Code Hang Up S15 Bit Mapped 1 = Disable High-Freq EQ MNP/V.42 Disabled in V.22 2 = Disable Online Fallback MNP/V.42 Disabled in V.22bis 4 = MNP/V.42 Disabled in V.32 8 = Reduced Non-ARQ TX Buffer Disable MNP Handshake 16 = Disable MNP Level 4 Disable MNP Level 4 32 = Set DEL=Backspace Disable MNP Level 3 64 = Unusual MNP-Incompatibility Unusual MNP-Incompatibility 128 = Custom Applications Disable V.42 136 = Disable V.42 Detect Phase S16 Test Modes 1 = Analog Loopback 2 = Dial Test 4 = Test Pattern 8 = Remote Digital Loopback 16 = Reserved 32 = Reserved 64 = Reserved 128 = Reserved S17 Reserved S18 &Tn Test Timeout (sec) S19 Inactivity Timeout (min) S20 Reserved S21 Break Length (1/100sec) S22 Xon Char S23 Xoff Char S24 DSR Pulse Time (1/50sec) S25 DTR Recognition Time (1/100sec) S26 RTS/CTS Delay Time (1/100sec) S27 Bit Mapped 1 = V21 Mode 2 = Disable TCM 4 = Disable V32 8 = Disable 2100hz 16 = Disable MNP Handshake Enable V23 Fallback 32 = Disable V.42 Disable V32bis 48 = Disable V.42 Detect Phase 64 = Reserved 128 = Unusual SW-Incompatibility Software Compatibility Mode S28 V32 Handshake Time (1/10sec) S29 V.21 answer mode fallback timer S30 Reserved S31 Reserved S32 Talk/Data Switch S32 Connection bit mapped operations. 0 = Disabled 1 = V.8 Call Indicate enable 1 = Originate Mode 2 = Enable V.8 mode 2 = Answer Mode 4 = Reserved 3 = Redial Last Number 8 = Disable V.34 modulation 4 = Dial Stored Number 0 16 = Disable V.34+ modulation 5 = Auto Answer Toggle 32 = Disable x2 modulation 6 = Reset Modem 64 = Disable V.90 modulation 7 = Initiate RDL 128 = Reserved 8 = Busy Toggle 9 = Execute Stored Cmd S33 V.34 & V.34+ Connection setup bit mapped control flags. 1 = Disable 2400 Symbol rate 2 = Disable 2743 Symbol rate 4 = Disable 2800 Symbol rate 8 = Disable 3000 Symbol rate 16 = Disable 3200 Symbol rate 32 = Disable 3429 Symbol rate 64 = Reserved 128 = Disable Shaping S34 Bit Mapped S34 V.34 & V.34+ Connection setup bit mapped control flags. 1 = Disable V32bis 1 = Disable 8S-2D trellis encoding 2 = Disable Enhanced V32 mode 2 = Disable 16S-4D trellis encoding 4 = Disable Quick V32 retrain 4 = Disable 32S-2D trellis encoding 8 = Enable V23 Fallback 8 = Disable 64S-4D trellis encoding 16 = Change MR to DSR 16 = Disable Non linear coding 32 = Enable MI/MIC 32 = Disable TX level deviation 64 = Disable RA Busy Msg 64 = Disable Pre-emphasis 128 = Disable Terbo 128 = Disable Pre-coding S35 Reserved S36 Reserved S37 Reserved S38 Disconnect Wait Time (sec) S39 Reserved S40 Reserved S41 # of Allowed Login Attempts S42 Remote Escape Code Char S43 Remote Escape Code Time (1/50sec) S44 Leased Line Delay Timer (sec) S51 Bit Mapped 1 = MNP/V.42 Disabled in V.22 2 = MNP/V.42 Disabled in V.22bis 4 = MNP/V.42 Disabled in V.32 8 = Reserved 16 = Reserved 32 = Reserved 64 = Reserved 128 = Enable phone exclusion delay S53 Bit Mapped 1 = Enable Dial Security 2 = Enable Autopass Fallback 4 = Enable Local Access Psw 8 = Reserved 16 = Reserved 32 = Reserved 64 = Reserved 128 = Reserved ATD$ ---- 0-9 Digits to Dial * Auxiliary Tone Dial Digit # Auxiliary Tone Dial Digit T Tone Dialing P Pulse Dialing R Call an Originate Only Modem , Pause (Wait for S8 Time) / Short Delay ; Remain in Command Mode After Dialing " Used to Dial Alpha Phone #'s W Wait for 2nd Dial Tone (X3-X7) @ Wait for an Answer (X3-X7) ! Flash Switch Hook Leds ---- ARQ : Error control SYN : Synchronous mode CS : Clear to Send RS : Request to Send MR : Modem Ready / Power TR : Terminal Ready SD : Send Data RD : Receive Data OH : Off Hook CD : Carrier Detect AA : Auto Answer HS : High Speed RS-232 PIN ASSIGNMENTS ---------------------- 1 Ground 2 Transmitted Data 3 Received Data 4 Request to Send 5 Clear to Send 6 Data Set Ready 7 Signal Ground 8 Carrier Detect 12 Speed Indicate 15 Sync TX Timing 17 Sync RX Timing 20 Data Terminal Ready 22 Ring Indicate 24 Sync TX Timing